co2.jpg

Co2 Fire Extinguisher

Capacity : 2, 3, 4, 5, 8 kg

Class : CarbonDi-Oxide Gas

ISI certified 15683

Co2 Fire Extinguishers are very effective against Petroleum, oil, solvent, flammable gasses, industrial gases and as well as electrical fires. 

ABC.jpg

ABC Fire Extinguisher

Capacity : 1, 2, 4, 6, 9 Kgs

Class : ABC Fire Extinguisher

ISI certified 15683

ABC Fire Extinguishers are very effective against all classes of fire risks. It can easily combat with A, B, and C classes of fire as well as electrical fires.

image.png

Mechanical Foam- AFFF

Capacity : 9 & 45 Ltr

Class : AFFF IS 4989

ISI certified 15683

AFFF Fire Extinguishers are very effective against Wood, textiles, paper, cloths jute, petroleum, oil, Aviation fuel, Volatile liquids etc.

water typer .jpg

WATER TYPE FIRE EXINGUISHER

  • The water type fire extinguisher is perfect for private homes and businesses because it uses the latest water mist technology.

  • When using this product on A, B, C, and F type fires, it is safe up to 1000 volts. It is also safe on live electrical equipment, up to 1000 volts. This product is marked with a Kitemark and is CE marked.

zone fire.jpg

Zone Fire Panel

  • AC input supply: 220 V AC 50 H2

  • DC input supply :  24 V DC

  • Operating voltage: 24 V DC

  • Normal Zone Voltage: 20.7 DC

  • Stand by current: 8.2 Micro Ampere

  • (EOL + detector’s)

  • Alarm current: 20-35 Mille Ampere

  • Alarm output: 2 V @ 1A

  • Maximum No. Of Detectors:  20 No.  n each Zone

  • Dimension of Panel: 13”x11”x4”

  • Colours of Panel : White, Red

water typer .jpg

WATER TYPE FIRE EXINGUISHER

  • The water type fire extinguisher is perfect for private homes and businesses because it uses the latest water mist technology.

  • When using this product on A, B, C, and F type fires, it is safe up to 1000 volts. It is also safe on live electrical equipment, up to 1000 volts. This product is marked with a Kitemark and is CE marked.

water typer .jpg

Water Type Fire Extinguisher

The water type fire extinguisher is perfect for private homes and businesses because it uses the latest water mist technology.

When using this product on A, B, C, and F type fires, it is safe up to 1000 volts. It is also safe on live electrical equipment, up to 1000 volts. This product is marked with a Kitemark and is CE marked.

Trolley Type Fire Extinguisher.jpg

ABC Dry Chemical Powder Trolly Fire Extinguisher

ABC fire extinguishers are often the ideal choice because they can put out many different types of fires. They use a dry chemical known as monoammonium phosphate that can quickly put out the fire. It is a pale-yellow powder that is used to extinguish three classes of fire. ABC fire extinguishers are considered “multi-purpose” extinguishers which can be used on Class A, B, C fires as well Electric Fire.

carbon dioxide trolley fire extinguisher.png

Carbon Dioxide Trolley Fire Extinguisher

C02 fire extinguishers are often The ideal choice for liquid & Gas started fires. Flammable liquids such as petrol and oil (Class B) & Flammable gases are highly compatible In nature. A single spark of fine can lead to an explosive fire incidence, which in no time can turn into an inferno. Our Co2 Fire Extinguishers are Packed with tremendous power, which cuts off the oxygen supply, and bring the temperature down drastically, Stopping the fire in seconds.

Fire-Detection-Alarm-Systems.jpg

Fire Alarm

We specialize in offering our customers with a high-quality selection of fire alarms. We employ the highest-quality materials and cutting-edge technologies to design the specified product in accordance with industry requirements.

Exit plan (1).jpg

Fire Escape Route Plan

Companies to operate emergency evacuation plans as a set of guidelines to help leave the workplace safely in the case of an emergency. Plans for evacuation during an emergency frequently include escape routes, the locations of selected safe spots, and the specific procedures to take in each circumstances.

Fire Ball.jpg

Fire Ball

Easy to use, No need for special maintenance, Safe and Effective, 360 degree Coverage

fire clynder refilling.jpg

Fire Cylinder AMC & Refilling

We do Fire extinguisher refilling and annual maintenance work for all our existing as well as new clients who are looking for refilling or AMC Services. 

First Aid Box 2.jpg

First Aid Kit Box

Fully equipped with first aid supplies for emergency. It comes with a box for storage. In case of an emergency, the First Aid Box is stocked with the necessary medications, bandages, ointments, lotions, and creams. Large size to storing ointment and lotion bottles. dividers for bandages, medications, and other things.

safety-training.jpg

Fire Safety Mock Drill

We are well-known for providing our customers with fire training and drill services. Physical training, security responsibilities, documentation, discipline, using fire fighting equipment, first aid, and investigations are all part of the training. Our clients receive the best services and solutions from our effective and knowledgeable employees.

smoke detector.jpg

Smoke Detector

Operating Voltage  :  DC (10.8 ~ 30) V
Frequency   : 3‐5 Seconds
Smoke Sensitivity : 1.51% /  ~ 2.73% /  obscuration
Reset Voltage  : Less than 1 volt
Reset : Less than 1 sec.
Alarm indication : 2 continuous emitting red LEDs
Weight  : 140 gram with base
Start up current  : 200 µA
Alarm current (Max) : 60 mA
Stand by current : 60 µA
Dimension : Dia 100mm, ht 46mm

flasher hooter.jpg

Fire Security Emergency Alarm

Power I/P   : 24V DC (16-33VDC)
Power O/P  : 105-110 db
Weight    :    192 gm
Current consumption  :  50-95 mA
Color : Red
Light Source & Color : High Power Cool white LED
Construction  : ABS Housing
Dimensions (mm) : L 139mm * D 78mm * W 139mm
Wiring : 2-Wire Type
Flash Rate : 2 Flash Per Second

voice hooter.jpg

Voice Hooter

Power I/P  :  12/24 V DC
Power O/P  :  90 db to 105 db
Weight  :  340 gm
Speaker  :  4 inch
Current consumption : 220 mA
Construction : ABS Housing / Metal Box Housing optional

stand.jpg

Floor Stand for Fire Extinguisher

Material: Mild steel

Mounting Type: Floor Mounting

zone fire.jpg

Zone Fire Panel

AC input supply: 220 V AC 50 H2

DC input supply :  24 V DC

Operating voltage: 24 V DC

Normal Zone Voltage: 20.7 DC

Stand by current: 8.2 Micro Ampere (EOL + detector’s)

Alarm current: 20-35 Mille Ampere

Alarm output: 2 V @ 1A

Maximum No Of Detectors: 20 No in each Zone

Dimension of Panel: 13”x11”x4”

Colors of Panel : White, Red

bottom of page